Deprecated: Implicit conversion from float 231.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 231.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 231.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 231.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 231.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 231.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 265.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 265.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 265.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Warning: imagejpeg(C:\Inetpub\vhosts\kidney.de\httpdocs\phplern\33434096.jpg): Failed to open stream: No such file or directory in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 117 Health+Secur 2021 ; 19 (4): 379-385 Nephropedia Template TP
gab.com Text
Twit Text FOAVip
Twit Text #
English Wikipedia
Respiratory Protection in a Time of Crisis: NIOSH Testing of International Respiratory Protective Devices for Emergency Use #MMPMID33434096
Andrews AS; Powers JR , Jr; Cichowicz JK; Coffey CC; Fries ML; Yorio PL; D'Alessandro MM
Health Secur 2021[Jul]; 19 (4): 379-385 PMID33434096show ga
National Institute for Occupational Safety and Health (NIOSH)-approved respirators are required by the Occupational Safety and Health Administration (OSHA) when personal respiratory protection is used in US occupational settings. During the COVID-19 pandemic, the demand for NIOSH-approved N95 filtering facepiece respirators overwhelmed the available supply. To supplement the national inventory of N95 respirators, contingency and crisis capacity strategies were implemented and incorporated a component that endorsed the use of non-NIOSH-approved respiratory protective devices that conformed to select international standards. The development and execution of this strategy required the collaborative effort of numerous agencies. The Food and Drug Administration temporarily authorized non-NIOSH-approved international respiratory protective devices through an emergency use authorization, OSHA relaxed their enforcement guidance concerning their use in US workplaces, and NIOSH initiated a supplemental performance assessment process to verify the quality of international devices. NIOSH testing revealed that many of the non-NIOSH-approved respiratory protective devices had filtration efficiencies below 95% and substantial inconsistencies in filtration performance. This article reports the results of the NIOSH testing to date and discusses how it has contributed to continuous improvement of the crisis strategy of temporarily permitting the use of non-NIOSH-approved respirators in US occupational settings during the COVID-19 pandemic.
|*COVID-19[MESH]
|*Public Health[MESH]
|Environmental Health/*standards[MESH]
|Filtration/instrumentation/*standards[MESH]
|Humans[MESH]
|Internationality[MESH]
|National Institute for Occupational Safety and Health, U.S./*standards[MESH]